GIMA K15 TOUCHSCREEN MULTIPARAMETER MONITOR
GIMA K15 TOUCHSCREEN MULTIPARAMETER MONITOR
GIMA K15 TOUCHSCREEN MULTIPARAMETER MONITOR
GIMA K15 TOUCHSCREEN MULTIPARAMETER MONITOR
GIMA K15 TOUCHSCREEN MULTIPARAMETER MONITOR
GIMA K15 TOUCHSCREEN MULTIPARAMETER MONITOR

GIMA K15 TOUCHSCREEN MULTIPARAMETER MONITOR

35309
€1,780.00
VAT excluded
€1,869.00 tax 5% incl.
ECG

• Input dynamic range: ±(0.5~5 mVp)

• Differential input impedance: =10 mO

• Bandwidth: - 0.05~150 Hz (diagnostic) - 0.5~40 Hz (monitoring) - 1~20 Hz (operation)

• CMRR: - =90 db (diagnostic) - =105 db (monitoring & operation)

• Sensitivity selection: ×1/4, ×1/2, ×1, ×2, ×4 and Auto

• Sweeping speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s

• HR measuring range: 15~350 bpm ±1% or ±2 bpm, whichever is greater

• Pacemaker pulse detection and rejection function RESP

• Measuring range: 0~120 rpm ±5% or ±2 rpm, whichever is greater TEMP

• Measuring range: 21.0~50.0 °C ±0.2 °C from 25~45 °C NIBP

• Technique: oscillometric method

• Typical measurement time: <30 seconds (adult cuff)

• NIBP measuring range SYS: - 40~275 mmHg (Adult) - 40~200 mmHg (Pediatric) - 40~135 mmHg (Neonate)

• NIBP measuring range DIA: - 10~210 mmHg (Adult) - 10~150 mmHg (Pediatric) - 10~95 mmHg (Neonate)

• NIBP measuring range MAP: - 20~230 mmHg (Adult) - 20~165 mmHg (Pediatric) - 20~110 mmHg (Neonate)

• NIBP measuring accuracy: - Mean difference: ±5 mmHg - Standard deviation: 8 mmHg

• NIBP measurement mode: Manual, Auto, Stat, Multi-cycle mode

• Auto measuring intervals: 1-480 min SpO2

• Technique: Dual-wavelength optical method

• Measuring range: 0%~100% ±2% for Spo2 range 70~100%

• PR measuring range: 30~250bpm ±2bpm or ±2%, whichever is greater

• Low perfusion performance: as low as 0.3%. CO2

• Technique: infrared optical method

• Sampling mode: Sidestream or mainstream

• Measuring range: 0~150 mmHg

• Measuring accuracy: - 0~40 mmHg ±2 mmHg - 41~70 mmHg ±5% of reading - 71~100 mmHg ±8% of reading - 101~150 mmHg ±10% of reading

• Flow rate: 50 ml/min ±10 ml/min (Sidestream) Other specifications

• Power supply: AC 100-240 V, 50/60 Hz, 60 VA

• Built-in lithium battery: 11.1V/4400 mah

• Display: 15 inch TFT display

• Alarming method: 3 levels audible-visible alarm

• Networking: Ethernet

• Safety standard: IEC 60601-1

 
K15 TOUCHSCREEN MULTIPARAMETER MONITOR 15" Multi-functional patient monitors, designed for monitoring the vital physiological signs of adult, pediatric and neonate patients. With the functions of real-time recording and displaying parameters, such as ECG, heart rate (HR), non-invasive blood pressure (NIBP), oxygen saturation (SpO2), respiration (RESP), temperature (TEMP), it allows comprehensive analysis of patient's physiological conditions. - ergonomic design with intuitive user interface - USB socket for data transfer and software upgrade - 9 traces on-screen waveforms - Windows style display view, easy to operate - visual and audible alarm for physiological and technical alarms - large capacity storage - suitable for use with original Nellcor sensors - protection against defibrillator discharge, resistance against the interference from electro-surgical unit; cardiac pacemaker pulse detection and inhibition. Internal software: GB, DE, FR, PT, ES, IT, PL, TR, RU. PC software only GB. 360° degree visible indicator with 3 level alarm. Lithium battery up to 2.5 hours continuous monitoring.

TECNICAL SPECIFICATIONS

ECG

• Input dynamic range: ±(0.5~5 mVp)

• Differential input impedance: =10 mO

• Bandwidth: - 0.05~150 Hz (diagnostic) - 0.5~40 Hz (monitoring) - 1~20 Hz (operation)

• CMRR: - =90 db (diagnostic) - =105 db (monitoring & operation)

• Sensitivity selection: ×1/4, ×1/2, ×1, ×2, ×4 and Auto

• Sweeping speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s

• HR measuring range: 15~350 bpm ±1% or ±2 bpm, whichever is greater

• Pacemaker pulse detection and rejection function RESP

• Measuring range: 0~120 rpm ±5% or ±2 rpm, whichever is greater TEMP

• Measuring range: 21.0~50.0 °C ±0.2 °C from 25~45 °C NIBP

• Technique: oscillometric method

• Typical measurement time: <30 seconds (adult cuff)

• NIBP measuring range SYS: - 40~275 mmHg (Adult) - 40~200 mmHg (Pediatric) - 40~135 mmHg (Neonate)

• NIBP measuring range DIA: - 10~210 mmHg (Adult) - 10~150 mmHg (Pediatric) - 10~95 mmHg (Neonate)

• NIBP measuring range MAP: - 20~230 mmHg (Adult) - 20~165 mmHg (Pediatric) - 20~110 mmHg (Neonate)

• NIBP measuring accuracy: - Mean difference: ±5 mmHg - Standard deviation: 8 mmHg

• NIBP measurement mode: Manual, Auto, Stat, Multi-cycle mode

• Auto measuring intervals: 1-480 min SpO2

• Technique: Dual-wavelength optical method

• Measuring range: 0%~100% ±2% for Spo2 range 70~100%

• PR measuring range: 30~250bpm ±2bpm or ±2%, whichever is greater

• Low perfusion performance: as low as 0.3%. CO2

• Technique: infrared optical method

• Sampling mode: Sidestream or mainstream

• Measuring range: 0~150 mmHg

• Measuring accuracy: - 0~40 mmHg ±2 mmHg - 41~70 mmHg ±5% of reading - 71~100 mmHg ±8% of reading - 101~150 mmHg ±10% of reading

• Flow rate: 50 ml/min ±10 ml/min (Sidestream) Other specifications

• Power supply: AC 100-240 V, 50/60 Hz, 60 VA

• Built-in lithium battery: 11.1V/4400 mah

• Display: 15 inch TFT display

• Alarming method: 3 levels audible-visible alarm

• Networking: Ethernet

• Safety standard: IEC 60601-1

STANDARD ACCESSORIES

- Adult SpO2 probe - NIBP adult cuff - SpO2 extension cable - ECG cable - Skin temperature probe - Power supply cable - Re-chargeable lithium battery - Dust-protective cover - Disposable electrode - Manual: GB, FR, IT, ES, PL, RU

unità
1 pz.
NSIS
1977794
CND
Z1203020202
GMDN
33586
Classe Medicale
II B
Dispositivo Medico
Dispositivo medico
27 Items
New
No reviews

16 other products in the same category:

Product added to compare.