ECG

• Input dynamic range: ±(0.5~5 mVp)

• Differential input impedance: =10 mO

• Bandwidth: - 0.05~150 Hz (diagnostic) - 0.5~40 Hz (monitoring) - 1~20 Hz (operation)

• CMRR: - =90 db (diagnostic) - =105 db (monitoring & operation)

• Sensitivity selection: ×1/4, ×1/2, ×1, ×2, ×4 and Auto

• Sweeping speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s

• HR measuring range: 15~350 bpm ±1% or ±2 bpm, whichever is greater

• Pacemaker pulse detection and rejection function RESP

• Measuring range: 0~120 rpm ±5% or ±2 rpm, whichever is greater TEMP

• Measuring range: 21.0~50.0 °C ±0.2 °C from 25~45 °C NIBP

• Technique: oscillometric method

• Typical measurement time: <30 seconds (adult cuff)

• NIBP measuring range SYS: - 40~275 mmHg (Adult) - 40~200 mmHg (Pediatric) - 40~135 mmHg (Neonate)

• NIBP measuring range DIA: - 10~210 mmHg (Adult) - 10~150 mmHg (Pediatric) - 10~95 mmHg (Neonate)

• NIBP measuring range MAP: - 20~230 mmHg (Adult) - 20~165 mmHg (Pediatric) - 20~110 mmHg (Neonate)

• NIBP measuring accuracy: - Mean difference: ±5 mmHg - Standard deviation: 8 mmHg

• NIBP measurement mode: Manual, Auto, Stat, Multi-cycle mode

• Auto measuring intervals: 1-480 min SpO2

• Technique: Dual-wavelength optical method

• Measuring range: 0%~100% ±2% for Spo2 range 70~100%

• PR measuring range: 30~250bpm ±2bpm or ±2%, whichever is greater

• Low perfusion performance: as low as 0.3%. CO2

• Technique: infrared optical method

• Sampling mode: Sidestream or mainstream

• Measuring range: 0~150 mmHg

• Measuring accuracy: - 0~40 mmHg ±2 mmHg - 41~70 mmHg ±5% of reading - 71~100 mmHg ±8% of reading - 101~150 mmHg ±10% of reading

• Flow rate: 50 ml/min ±10 ml/min (Sidestream) Other specifications

• Power supply: AC 100-240 V, 50/60 Hz, 60 VA

• Built-in lithium battery: 11.1V/4400 mah

• Display: 12 inch TFT display

• Alarming method: 3 levels audible-visible alarm

• Networking: Ethernet

• Safety standard: IEC 60601-1

 
K12 MULTIPARAMETER MONITOR 12" Multi-functional patient monitors, designed for monitoring the vital physiological signs of adult, pediatric and neonate patients. With the functions of real-time recording and displaying parameters, such as ECG, heart rate (HR), non-invasive blood pressure (NIBP), oxygen saturation (SpO2), respiration (RESP), temperature (TEMP), it allows comprehensive analysis of patient's physiological conditions. - ergonomic design with intuitive user interface - USB socket for data transfer and software upgrade - 9 traces on-screen waveforms - Windows style display view, easy to operate - visual and audible alarm for physiological and technical alarms - large capacity storage - suitable for use with original Nellcor sensors - protection against defibrillator discharge, resistance against the interference from electro-surgical unit; cardiac pacemaker pulse detection and inhibition. Internal software: GB, DE, FR, PT, ES, IT, PL, TR, RU. PC software only GB. 360° degree visible indicator with 3 level alarm. Lithium battery up to 2.5 hours continuous monitoring.

TECNICAL SPECIFICATIONS

ECG

• Input dynamic range: ±(0.5~5 mVp)

• Differential input impedance: =10 mO

• Bandwidth: - 0.05~150 Hz (diagnostic) - 0.5~40 Hz (monitoring) - 1~20 Hz (operation)

• CMRR: - =90 db (diagnostic) - =105 db (monitoring & operation)

• Sensitivity selection: ×1/4, ×1/2, ×1, ×2, ×4 and Auto

• Sweeping speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s

• HR measuring range: 15~350 bpm ±1% or ±2 bpm, whichever is greater

• Pacemaker pulse detection and rejection function RESP

• Measuring range: 0~120 rpm ±5% or ±2 rpm, whichever is greater TEMP

• Measuring range: 21.0~50.0 °C ±0.2 °C from 25~45 °C NIBP

• Technique: oscillometric method

• Typical measurement time: <30 seconds (adult cuff)

• NIBP measuring range SYS: - 40~275 mmHg (Adult) - 40~200 mmHg (Pediatric) - 40~135 mmHg (Neonate)

• NIBP measuring range DIA: - 10~210 mmHg (Adult) - 10~150 mmHg (Pediatric) - 10~95 mmHg (Neonate)

• NIBP measuring range MAP: - 20~230 mmHg (Adult) - 20~165 mmHg (Pediatric) - 20~110 mmHg (Neonate)

• NIBP measuring accuracy: - Mean difference: ±5 mmHg - Standard deviation: 8 mmHg

• NIBP measurement mode: Manual, Auto, Stat, Multi-cycle mode

• Auto measuring intervals: 1-480 min SpO2

• Technique: Dual-wavelength optical method

• Measuring range: 0%~100% ±2% for Spo2 range 70~100%

• PR measuring range: 30~250bpm ±2bpm or ±2%, whichever is greater

• Low perfusion performance: as low as 0.3%. CO2

• Technique: infrared optical method

• Sampling mode: Sidestream or mainstream

• Measuring range: 0~150 mmHg

• Measuring accuracy: - 0~40 mmHg ±2 mmHg - 41~70 mmHg ±5% of reading - 71~100 mmHg ±8% of reading - 101~150 mmHg ±10% of reading

• Flow rate: 50 ml/min ±10 ml/min (Sidestream) Other specifications

• Power supply: AC 100-240 V, 50/60 Hz, 60 VA

• Built-in lithium battery: 11.1V/4400 mah

• Display: 12 inch TFT display

• Alarming method: 3 levels audible-visible alarm

• Networking: Ethernet

• Safety standard: IEC 60601-1

STANDARD ACCESSORIES

- Adult SpO2 probe - NIBP adult cuff - SpO2 extension cable - ECG cable - Skin temperature probe - Power supply cable - Re-chargeable lithium battery - Dust-protective cover - Disposable electrode - Manual: GB, FR, IT, ES, PL, RU