• SpO2 - Measuring range: 35%-100% - Accuracy: ±3% (70-100%)

• Pulse Rate - Measuring range: 30-240 bpm - Accuracy*: ±2% or ±2 bpm (whichever is greater) *Root-mean-square value of deviation according to ISO 1919

• NIBP - Pressure range: 0-300 mmHg (0-39.9kpa) - Accuracy: ±3 mmHg - Measuring range: Systolic pressure: 60-240 mmHg - Diastolic pressure: 30-180 mmHg

• TEMP - Measuring range: 32-43.0°C - Accuracy: ±0.2°C (35-42°C) - ±0.3°C (other) - Measuring time: <5 s

• ECG (Optional) - Heart Rate measuring range: 30-240 bpm - Heart Rate accuracy: ±2 bpm or ±2% whichever is greater - Display scale: 5.0 mm/mV ±10% - Common-mode rejection ratio (CMRR): =60 dB

• Blood Glucose (Optional) - Measuring range: 20 to 600 mg/DL - SEE other specification at page

• Power Supply - Battery: 3.7 V built-in Li-ion battery - Operating voltage: 3.6-4.2 VDC - Operating current: =800 mA - Charger: 100 - 240 VAC, 50/60 Hz, 5 VDC or USB

 
PC-300 handheld Spot-check monitor measures SpO2, Pulse Rate, NIBP and TEMP. Widely used in hospitals, clinics and family daily measurement. Equipped with Bluetooth and USB interface, allows to transfer data to PC, tablets and smartphone (Android and iOS). - up to 6000 groups NIBP data storage, up to 100 different patients (each user can store 999 measurement records) - quick ear probe TEMP measurement result in 5 seconds - data transfer to PC/Smartphone by USB or Bluetooth - optional NIBP pediatric cuff and SpO2 pediatric probe - optional ECG and Glucometer - built-in rechargeable lithium battery - communication protocols available on request Size: 165 x 96 x 68 mm.

TECNICAL SPECIFICATIONS

• SpO2 - Measuring range: 35%-100% - Accuracy: ±3% (70-100%)

• Pulse Rate - Measuring range: 30-240 bpm - Accuracy*: ±2% or ±2 bpm (whichever is greater) *Root-mean-square value of deviation according to ISO 1919

• NIBP - Pressure range: 0-300 mmHg (0-39.9kpa) - Accuracy: ±3 mmHg - Measuring range: Systolic pressure: 60-240 mmHg - Diastolic pressure: 30-180 mmHg

• TEMP - Measuring range: 32-43.0°C - Accuracy: ±0.2°C (35-42°C) - ±0.3°C (other) - Measuring time: <5 s

• ECG (Optional) - Heart Rate measuring range: 30-240 bpm - Heart Rate accuracy: ±2 bpm or ±2% whichever is greater - Display scale: 5.0 mm/mV ±10% - Common-mode rejection ratio (CMRR): =60 dB

• Blood Glucose (Optional) - Measuring range: 20 to 600 mg/DL - SEE other specification at page

• Power Supply - Battery: 3.7 V built-in Li-ion battery - Operating voltage: 3.6-4.2 VDC - Operating current: =800 mA - Charger: 100 - 240 VAC, 50/60 Hz, 5 VDC or USB

STANDARD ACCESSORIES

• SpO2 adult probe

• NIBP adult cuff

• Ear thermometer (probe covers not included)

• Lithium battery with charger

• Carrying bag

• User manual: GB, FR, IT, ES

CND
Z1203020202
GMDN
57960
Parafarm
977815493
Classe Medicale
II A
Dispositivo Medico
Dispositivo medico
unità
1 pz.
NSIS
1316220
228 Items
New
No reviews

16 other products in the same category:

Product added to compare.