DIATERMO MB 400D HOSPITAL
• Maximum out power monopolar pure CUT: 400 W - 300 Ohm
• Maximum out power monopolar cut-coag CUT80%: 350 W - 300 Ohm
• Maximum out power monopolar cut-coag CUT60%: 250 W - 300 Ohm
• Maximum out power monopolar cut-coag CUT40%: 200 W - 300 Ohm
• Maximum out power monopolar cut ENHANCED: 250 W - 500 Ohm
• Maximum out power monopolar cut-coag BLEND: 250 W - 300 Ohm
• Maximum out power monopolar coag SPEEDY: 120 W - 500 Ohm
• Maximum out power monopolar coag DEEP: 120 W - 200 Ohm
• Maximum out power monopolar coag SPRAY 100 W - 2000 Ohm
• Maximum out power monopolar coag SPRAY ARGON: 100 W - 2000 Ohm
• Maximum out power bipolar CUT 95 W - 150 Ohm
• Maximum out power bipolar cut-coag CUT80%: 95 W - 150 Ohm
• Maximum out power bipolar cut-coag CUT60%: 95 W - 150 Ohm
• Maximum out power bipolar cut-coag CUT40%: 60 W - 150 Ohm
• Maximum out power bipolar cut-coag BLEND: 90 W - 150 Ohm
• Maximum out power bipolar cut-coag BLEND: 70 W - 100 Ohm
• Working frequency monopolar/bipolar: 425 kHz / 525 kHz
• Patient circuit: F
• Selectable input voltage: 115-230 Vac
• Mains frequency: 50-60 Hz
• Electrical input voltage: 1000 VA
• Size WxHxD: 470 x 150 x 400 mm
• Weight: 17,5 kgs
• Controls: Patient/Plate circuit monitoring, Output power monitoring, Self check control
• Safety: EN60601-1, EN60601-1-2, EN60601-2-2,
• Electrical Class: I CF, MDD 93/42/EC Class: II b
CARATTERISTICHE TECNICHE
• Maximum out power monopolar pure CUT: 400 W - 300 Ohm
• Maximum out power monopolar cut-coag CUT80%: 350 W - 300 Ohm
• Maximum out power monopolar cut-coag CUT60%: 250 W - 300 Ohm
• Maximum out power monopolar cut-coag CUT40%: 200 W - 300 Ohm
• Maximum out power monopolar cut ENHANCED: 250 W - 500 Ohm
• Maximum out power monopolar cut-coag BLEND: 250 W - 300 Ohm
• Maximum out power monopolar coag SPEEDY: 120 W - 500 Ohm
• Maximum out power monopolar coag DEEP: 120 W - 200 Ohm
• Maximum out power monopolar coag SPRAY 100 W - 2000 Ohm
• Maximum out power monopolar coag SPRAY ARGON: 100 W - 2000 Ohm
• Maximum out power bipolar CUT 95 W - 150 Ohm
• Maximum out power bipolar cut-coag CUT80%: 95 W - 150 Ohm
• Maximum out power bipolar cut-coag CUT60%: 95 W - 150 Ohm
• Maximum out power bipolar cut-coag CUT40%: 60 W - 150 Ohm
• Maximum out power bipolar cut-coag BLEND: 90 W - 150 Ohm
• Maximum out power bipolar cut-coag BLEND: 70 W - 100 Ohm
• Working frequency monopolar/bipolar: 425 kHz / 525 kHz
• Patient circuit: F
• Selectable input voltage: 115-230 Vac
• Mains frequency: 50-60 Hz
• Electrical input voltage: 1000 VA
• Size WxHxD: 470 x 150 x 400 mm
• Weight: 17,5 kgs
• Controls: Patient/Plate circuit monitoring, Output power monitoring, Self check control
• Safety: EN60601-1, EN60601-1-2, EN60601-2-2,
• Electrical Class: I CF, MDD 93/42/EC Class: II b
DOTAZIONE STANDARD
1 - Cavo alimentazione 5 m 1 - Manipolo autoclavabile con due pulsanti (30536) 5 - Manipolo ster. a freddo con due pulsanti (30551) 1 - Cavo per placca (30559) 5 - Placche monouso Rem (30493) 2 - Pedaliera doppia stagna HP 3 - Elettrodo a lama corto 7 cm 3 - Elettrodo a lama lungo 16 cm 3 - Elettrodo a sfera corto Ø 4 mm, 6 cm 1 - Spugnetta pulisci elettrodo 1 - Manuale d’uso (IT, GB) 1 - Manuale di servizio (IT, GB)
- Classe Medicale
- II B
- Dispositivo Medico
- Dispositivo medico
- unità
- 1 pz.
- NSIS
- 514978
- CND
- Z12010902
- GMDN
- 44776