• Maximum out power monopolar pure CUT: 400 W - 300 Ohm

• Maximum out power monopolar cut-coag CUT80%: 350 W - 300 Ohm

• Maximum out power monopolar cut-coag CUT60%: 250 W - 300 Ohm

• Maximum out power monopolar cut-coag CUT40%: 200 W - 300 Ohm

• Maximum out power monopolar cut ENHANCED: 250 W - 500 OOhm

• Maximum out power monopolar cut-coag BLEND: 250 W - 300 Ohm

• Maximum out power monopolar coag SPEEDY: 120 W - 500 Ohm

• Maximum out power monopolar coag DEEP: 120 W - 200 Ohm

• Maximum out power monopolar coag SPRAY: 100 W - 2000 Ohm

• Maximum out power monopolar coag SPRAY ARGON: 100 W - 2000 Ohm

• Maximum out power bipolar CUT 95 W - 150 Ohm

• Maximum out power bipolar cut-coag CUT80%: 95 W - 150 Ohm

• Maximum out power bipolar cut-coag CUT60%: 95 W - 150 Ohm

• Maximum out power bipolar cut-coag CUT40%: 60 W - 150 Ohm

• Maximum out power bipolar cut-coag BLEND: 90 W - 150 Ohm

• Maximum out power bipolar cut-coag BLEND: 70 W - 100 Ohm

• Working frequency monopolar/bipolar: 425 kHz / 525 kHz

• Patient circuit: F

• Selectable input voltage: 115-230 Vac

• Mains frequency: 50-60 Hz

• Electrical input voltage: 1000 VA

• Size WxHxD: 470 x 150 x 400 mm

• Weight: 17.5 kgs

• Controls: Patient/Plate circuit monitoring, Output power monitoring, Self check control

• Safety: EN60601-1, EN60601-1-2, EN60601-2-2, Electrical Class: I CF, MDD 93/42/EC Class: II b

 
High frequency electrosurgical equipment suitable to deliver current for monopolar cut and coagulated cut (with different levels of coagulation), bipolar cut and coagulation. TWIN OPERATIVE ACTIVITY - two output channels for monopolar cutting - two independent setting and output channels for the most frequent monopolar coagulation CONTROLLED CUTTING PROCEDURES - enhanced cutting current for eschar free incision - cutting current with selectable coagulating property for bleeding controlled dissection - low capacitance coupling by slow BLEND current for endoscopic procedures TWIN CONTROLLED COAGULATION PROCEDURES - SPEEDY coagulation and DEEP coagulation available to two operators - SPRAY coagulation by hand switch or foot switch controls EXTENSIVE BIPOLAR FEATURES - bipolar cutting current with selectable bleeding control - slow BLEND cutting current - automatic Start/Stop coagulation functions SURGEON AND PATIENT TOTAL SAFETY· - acceptability of contact impedance between patient body and return electrode continuously monitored by Skin Plate Electronic Control (SPEC) - H.F. leakage currents continuously monitored - mains fluctuation automatically compensated before delivery of HF power PERSONALIZED PROCEDURES - independent choice of coagulation currents and power levels by each of two operators - up to 10 procedures can be configured and re-called EXTENSION DRIVER AND INTERLOCK SIGNALS - driven output connection to external Argon Plasma unit and Smoke Evacuator unit AUTOMATIC SELF DIAGNOSIS - automatic diagnostic control of the complete functionality of electronic unit and connected accessories with coded report of failures SUITABLE IN: - OUTPATIENT SURGERY - GENERAL SURGERY - PAEDIATRIC SURGERY - PLASTIC SURGERY - THORAX SURGERY - VASCULAR SURGERY - DERMATOLOGY - ENDOSCOPY - GASTROENTEROLOGY - GYNAECOLOGY - NEUROSURGERY - ORTHOPEDICS - OTORHINOLARINGOLOGY - PNEUMOLOGY - UROLOGY - VETERINARY

TECNICAL SPECIFICATIONS

• Maximum out power monopolar pure CUT: 400 W - 300 Ohm

• Maximum out power monopolar cut-coag CUT80%: 350 W - 300 Ohm

• Maximum out power monopolar cut-coag CUT60%: 250 W - 300 Ohm

• Maximum out power monopolar cut-coag CUT40%: 200 W - 300 Ohm

• Maximum out power monopolar cut ENHANCED: 250 W - 500 OOhm

• Maximum out power monopolar cut-coag BLEND: 250 W - 300 Ohm

• Maximum out power monopolar coag SPEEDY: 120 W - 500 Ohm

• Maximum out power monopolar coag DEEP: 120 W - 200 Ohm

• Maximum out power monopolar coag SPRAY: 100 W - 2000 Ohm

• Maximum out power monopolar coag SPRAY ARGON: 100 W - 2000 Ohm

• Maximum out power bipolar CUT 95 W - 150 Ohm

• Maximum out power bipolar cut-coag CUT80%: 95 W - 150 Ohm

• Maximum out power bipolar cut-coag CUT60%: 95 W - 150 Ohm

• Maximum out power bipolar cut-coag CUT40%: 60 W - 150 Ohm

• Maximum out power bipolar cut-coag BLEND: 90 W - 150 Ohm

• Maximum out power bipolar cut-coag BLEND: 70 W - 100 Ohm

• Working frequency monopolar/bipolar: 425 kHz / 525 kHz

• Patient circuit: F

• Selectable input voltage: 115-230 Vac

• Mains frequency: 50-60 Hz

• Electrical input voltage: 1000 VA

• Size WxHxD: 470 x 150 x 400 mm

• Weight: 17.5 kgs

• Controls: Patient/Plate circuit monitoring, Output power monitoring, Self check control

• Safety: EN60601-1, EN60601-1-2, EN60601-2-2, Electrical Class: I CF, MDD 93/42/EC Class: II b

STANDARD ACCESSORIES

1 - Power supply cord 5 m 1 - Two-button autoclavable handle (30536) 5 - Two-button cold sterilizable handle (30551) 1 - Cable for flat plate (30559) 5 - Rem disposable ground pads (30493) 2 - HP double Water proof foot switch 3 - Short, general surgery blade electrode 7 cm 3 - Long, general surgery blade electrode 16 cm 3 - Short, general surgery ball electrode Ø 4 mm, 6 cm 1 - Electrode brush 1 - User manual (IT, GB) 1 - Service manual (IT, GB)

CND
Z12010902
GMDN
44776
Classe Medicale
II B
Dispositivo Medico
Dispositivo medico
unità
1 pz.
NSIS
514978
7 Items
New
No reviews

4 other products in the same category:

Product added to compare.