PC-3000 MULTI-PARAMETER PATIENT MONITOR
PC-3000 MULTI-PARAMETER PATIENT MONITOR
PC-3000 MULTI-PARAMETER PATIENT MONITOR
PC-3000 MULTI-PARAMETER PATIENT MONITOR
PC-3000 MULTI-PARAMETER PATIENT MONITOR
PC-3000 MULTI-PARAMETER PATIENT MONITOR
PC-3000 MULTI-PARAMETER PATIENT MONITOR
PC-3000 MULTI-PARAMETER PATIENT MONITOR
PC-3000 MULTI-PARAMETER PATIENT MONITOR
PC-3000 MULTI-PARAMETER PATIENT MONITOR
PC-3000 MULTI-PARAMETER PATIENT MONITOR
PC-3000 MULTI-PARAMETER PATIENT MONITOR

PC-3000 MULTI-PARAMETER PATIENT MONITOR

35134
€1,060.00
VAT excluded
€1,113.00 tax 5% incl.
NIBP Monitoring Measuring method: Automauc measurement by oscillating method Initial cuff inflation pressure: (Adult mode: < 180 mmHg) (Infant mode: < 120 mmHg) Overpressure protection limit: (Adult mode: 300 mmHg) (Infant mode: 240 mmHg) Measuring range Systolic pressure: (Adult: 40-225 mmHg) (Infant: 40-200 mmHg) Diastolic pressure: (Adult: 20-215 mmHg) (Infant: 20-165 mmHg) Mean arterial pressure: (Adult: 10-195 mmHg) (Infant: 10-150 mmHg) Measurement accuracy: (Systolic ± 10%) (Diastolic ± 10%) (MAP ± 10%) Measurement mode: Manual, Auto, STAT Automatic measuring: 1-240min TEMP Monitoring Measuring range, accuracy: 25.0 - 45.0°C, ± 0.2°C SpO2 & Pulse Rate Monitoring Trasducer: dual-wave lenght LED SpO2 measuring range: 35% - 100% Low perfusion capability: 0.4% - 5% SpO2 display accuracy: 70% - 100% ±3% PR measuring range: 30 bpm - 250 bpm ± 2 bpm ECG monitoring Hearth rate measurement: ± 0.4 mVp - ± 5 mVp Hearth rate display range: 20 - 250 bpm Display accuracy: ± 1% or ± 2 bpm, whichever is greater (Wide option of screen views available) Heart rate alarm delay time: = 10s Sensitivity selection: Auto, x1/2, x1, x2, x4 (tolerance: = 5%) Sweeping speed: 12.5 mm/s, 25 mm/s, 50 mm/s (tolerance: = 10%) Common-mode rejection ratio: = 89 dB Frequency response mode: (Monitoring: 0.5 - 40 Hz) (Diagnostic: 0.05 - 75 Hz) RESP Monitoring Monitoring range, accuracy: 0 - 120 rpm, ±5% or 2 rpm, whichever is greater RESP alarm range: 0 - 100 bpm ± 10% Other Technical Specifications Power supply: 100 - 250 Vac, 50/60 Hz <80VA Networking port: serial/Net port

 
PC 3000 Multi Parameter Patient Monitor: - 7'' high resolution colour TFT display, 5-channel waveform display - standard parameters: ECG, RESP, Sp02, NIBP, 2-TEMP, PR; Arrhythmia and ST segment analysis - up to 12,000 groups parameter data & 60-hour ECG waveform storage and recall - 1,000-hour graphic and tabular trends for all parameters - 7-channel ECG simultaneous waveforms display - protection against interference from defibrillator, electrosurgical knife - adult/pediatric measurement modes - visual and audible alarms; networking capability - carrying handle with bed-hooks Internal software: GB, IT, FR, ES, PT, PL, CZ, TR, CN.

TECNICAL SPECIFICATIONS

NIBP Monitoring Measuring method: Automauc measurement by oscillating method Initial cuff inflation pressure: (Adult mode: < 180 mmHg) (Infant mode: < 120 mmHg) Overpressure protection limit: (Adult mode: 300 mmHg) (Infant mode: 240 mmHg) Measuring range Systolic pressure: (Adult: 40-225 mmHg) (Infant: 40-200 mmHg) Diastolic pressure: (Adult: 20-215 mmHg) (Infant: 20-165 mmHg) Mean arterial pressure: (Adult: 10-195 mmHg) (Infant: 10-150 mmHg) Measurement accuracy: (Systolic ± 10%) (Diastolic ± 10%) (MAP ± 10%) Measurement mode: Manual, Auto, STAT Automatic measuring: 1-240min TEMP Monitoring Measuring range, accuracy: 25.0 - 45.0°C, ± 0.2°C SpO2 & Pulse Rate Monitoring Trasducer: dual-wave lenght LED SpO2 measuring range: 35% - 100% Low perfusion capability: 0.4% - 5% SpO2 display accuracy: 70% - 100% ±3% PR measuring range: 30 bpm - 250 bpm ± 2 bpm ECG monitoring Hearth rate measurement: ± 0.4 mVp - ± 5 mVp Hearth rate display range: 20 - 250 bpm Display accuracy: ± 1% or ± 2 bpm, whichever is greater (Wide option of screen views available) Heart rate alarm delay time: = 10s Sensitivity selection: Auto, x1/2, x1, x2, x4 (tolerance: = 5%) Sweeping speed: 12.5 mm/s, 25 mm/s, 50 mm/s (tolerance: = 10%) Common-mode rejection ratio: = 89 dB Frequency response mode: (Monitoring: 0.5 - 40 Hz) (Diagnostic: 0.05 - 75 Hz) RESP Monitoring Monitoring range, accuracy: 0 - 120 rpm, ±5% or 2 rpm, whichever is greater RESP alarm range: 0 - 100 bpm ± 10% Other Technical Specifications Power supply: 100 - 250 Vac, 50/60 Hz <80VA Networking port: serial/Net port

STANDARD ACCESSORIES

• 1 ECG cable

• 1 Adult SpO2 probe

• 1 AC power adapter

• 1 Li-ion battery

• 1 NIBP cuff

• 1 Body surface temperature trasducer

• 1Power cable

• 10 disposable electrodes

• User manual: IT, GB, FR

Dispositivo Medico
Dispositivo medico
unità
1 pz.
NSIS
1316206
CND
Z1203020201
GMDN
33586
Parafarm
977815481
Classe Medicale
II B