RIESTER RBP-100 BLOOD PRESSURE MONITOR - 1740 - table
RIESTER RBP-100 BLOOD PRESSURE MONITOR - 1740 - table
RIESTER RBP-100 BLOOD PRESSURE MONITOR - 1740 - table
RIESTER RBP-100 BLOOD PRESSURE MONITOR - 1740 - table
RIESTER RBP-100 BLOOD PRESSURE MONITOR - 1740 - table
RIESTER RBP-100 BLOOD PRESSURE MONITOR - 1740 - table

RIESTER RBP-100 BLOOD PRESSURE MONITOR - 1740 - table

49960
€245.00
VAT excluded
€298.90 tax 22% incl.
Measurement mode: oscillometric, auscultatory Measurement rate: - systolic: 60-255 mmHg - diastolic: 30-200 mmHg - pulse: 40-200 bpm Accuracy: - static: ±3 mmHg - pulse: ±5% Latex free cuffs: M: 22-32cm, L-XL: 32-52cm Cuff pressure: 0-310 mmHg Power supply: AC/DC Adapter 7.5V/1.5A NIMH AA 4.8V 2400 mAh rechargeable battery pack Battery: 1.000 measurements per full charge Size - weight: 170x135x41 mm - 510g (device only) Certificates: ISO EN13485, Medical Device Class IIa

 
RIESTER RBP-100 B.P. MONITOR - 1740 - table Clinical grade digital blood pressure monitor for fast and reliable readings. Clinically validated to international standards BHS, ESH, AAMI. Clinically validated for patients with special conditions: hypertension, diabetes, pregnancy, pre-eclampsia, arteriosclerosis, end-stage renal disease, obesity, elderly and children > 3 years of age. Two measurement modes: auscultatory (manual) and oscillometric (automated). Auscultatory mode with auto-deflate (3 mmHg/sec) provides consistent patient BP measurement and allows clinicians to verify automated readings without removing the cuff. Average mode (3x readings) allows for a more objective measurement for clinicians and helps mitigate the risk of elevated readings due to white coat hypertension. Interval settings in average mode 15, 30, 45, 60 sec. It measures BP and pulse range, systolic, diastolic, heart rate and MAP. - easy to read 4” LCD screen - arrythmia detection - large memory: 210 readings - easy to use one touch operation - display panel with WHO Blood Pressure Value Classification (colour coded) Supplied with 2.5 m air tube, 2 cuffs (M and L-XL), NiMH battery pack, AC/DC adapter (EU, US, UK, Austr.). Multilingual manual (GB, FR, IT, ES, DE, RU)

TECNICAL SPECIFICATIONS

Measurement mode: oscillometric, auscultatory Measurement rate: - systolic: 60-255 mmHg - diastolic: 30-200 mmHg - pulse: 40-200 bpm Accuracy: - static: ±3 mmHg - pulse: ±5% Latex free cuffs: M: 22-32cm, L-XL: 32-52cm Cuff pressure: 0-310 mmHg Power supply: AC/DC Adapter 7.5V/1.5A NIMH AA 4.8V 2400 mAh rechargeable battery pack Battery: 1.000 measurements per full charge Size - weight: 170x135x41 mm - 510g (device only) Certificates: ISO EN13485, Medical Device Class IIa

Classe Medicale
II A
unità
1 pz.