RIESTER RVS-100 MULTIPARAMETER MONITOR - 1960-RRBPE
TECNICAL SPECIFICATIONS
Clinical-grade NIBP (non-invasive blood pressure) Measuring method: automatic oscillometric Measurement range: Adult: [SYS 30-270 mmHg] [DIA 10-220 mmHg] [MAP 20-235 mmHg] Pediatric: [SYS 30-235 mmHg] [DIA 10-220 mmHg] [MAP 20-225 mmHg] Neonate: [SYS 30-135 mmHg] [DIA 10-110 mmHg] [MAP 20-125 mmHg] Cuff pressure range: 0-280 mmHg, resolution 1 mmHg Pressure accuracy: Static ±3 mmHg Clinic ±5 mmHg, standard deviation = 8 mmHg Pulse rate range: 40-240 bpm, accuracy 1 bpm Initial inflation pressure: [Adult 160 mmHg] [Pediatric 130 mmHg] [Neonate 75 mmHg] Double overpressure protection (hardware and software) [Adult 297 ± 3 mmHg] [Pediatric 252 ± 3 mmHg] [Neonate 147 ± 3 mmHg] Alarm range: SYS, DIA, MAP 0 - 300 mmHg Riester SpO2 Measurement range: 0-100 %, resolution 1% Accuracy: ±2% (70 to 100%) - ±3% (40 to 69%) Unspecified (0 % to 39 %) Alarm range: 0-100 % Average time: 4 sec, 8 sec, 16 sec Pulse rate Measurement range: 20-250 bpm, resolution 1 bpm Accuracy: ±1 % or ± 1 bpm whichever is greater Predictive thermometer Oral (Quick Mode) non-fever temps: 3 - 5 seconds / fever temps: 8 - 10 seconds Oral (Standard Mode): 6-10 seconds Measurement accuracy: 35.5 - 42ºC ± 0.1ºC (± 0.2ºF) Monitor Alarm: Visible LEDs (Red, Yellow, Cyan) Audible Speaker Audible alarm, QRS tone Supports Pitch Tone and multi-level volume Alarm tones meet the requirement of IEC 60601-1-8 Pressure: 45 to 85 dB test distance 1 meter from the tone Ports: 1 AC power inlet 1 standard RJ45 interfaces.100 BASE-TX, IEEE 802.3 4 USB ports 1 Equipotential grounding point 1 RJ11 connector for nurse call DC out port 15V/1.2 A Power Supply: 100 - 240 V AC, 50/60 Hz Battery: Lithium-Ion, rechargeable battery, 10.8 V DC, 6,600 mAh Charging time to a 100%: 6 hours Operating time approx. 11 hours (new and fully charged battery with connected SpO2, Temp and NIBP on AUTO mode (15 minutes interval)) Low battery indicator and charging battery indicator Monitor dimensions: 303x110x h 230 mm (11.93x9.05x4.33 inches) Weight: 3600 g, (7.94 lb) including temp module, printer
STANDARD ACCESSORIES
SpO2 adult sensor SpO2 extension cable Oral temperature probe Probe covers NIBP extension tube 2 cuffs (adult and adult large with connectors) Manual (GB, IT . On request FR, DE, ES , RU)
- Classe Medicale
- II B
- unità
- 1 pz.