GIMA FC 700 FOETAL MONITOR

GIMA FC 700 FOETAL MONITOR

29520
Out-of-Stock
€1,350.00
VAT excluded
€1,647.00 tax 22% incl.

• Dimensions: 296 x 92.5 x h 305.5 - approx. 2.9 kg

• Display: 7 segment LED - 2 channels (FHR, UC)

• Thermal printer print speed: 1, 2, 3 cm/min, paper feeding function

• Power adaptor - input: 100-240 VAC, 50-60 Hz, 1.2 A - output: 18 VDC, 2.5 A

• External link: RS-232C

• Foetal heart rate - input signal: ultrasound pulsed doppler - ultrasound frequency: 1.0 Mhz - ultrasound power: <10 mW/cm2 - FHR detection method: auto correlation - FHR range: 50-240 bpm ±1 bpm (120-160)

• Uterine contraction - reference (zero) control: one touch switch - measurement range: 0-99 units

• Foetal movement measurement detection source: ultrasound pulsed doppler

• Auto CTG analysis - average baseline FHR - number of UC - number of acceleration - number of deceleration (late, early, variable) - Tachycardia (moderate, severe) - Bradychardia (moderate, severe)


 
Cost-effective single foetal monitor Extreme ultrasound doppler sensitivity: - high-accuracy with 1 Mhz frequency - automatic/manual Foetal Movement detection - auto NST (Non-stress test) function from 10 min. to 1 hour Data printout - CTG analysis printing - A4 size chart paper with perforation line - plain thermal fax paper usable - print speed 1, 2, 3 cm/min Easy-to-use - one- touch operation and easy setup - alarm function (FHR high-low) - s/w upgrade via internet

TECNICAL SPECIFICATIONS

• Dimensions: 296 x 92.5 x h 305.5 - approx. 2.9 kg

• Display: 7 segment LED - 2 channels (FHR, UC)

• Thermal printer print speed: 1, 2, 3 cm/min, paper feeding function

• Power adaptor - input: 100-240 VAC, 50-60 Hz, 1.2 A - output: 18 VDC, 2.5 A

• External link: RS-232C

• Foetal heart rate - input signal: ultrasound pulsed doppler - ultrasound frequency: 1.0 Mhz - ultrasound power: <10 mW/cm2 - FHR detection method: auto correlation - FHR range: 50-240 bpm ±1 bpm (120-160)

• Uterine contraction - reference (zero) control: one touch switch - measurement range: 0-99 units

• Foetal movement measurement detection source: ultrasound pulsed doppler

• Auto CTG analysis - average baseline FHR - number of UC - number of acceleration - number of deceleration (late, early, variable) - Tachycardia (moderate, severe) - Bradychardia (moderate, severe)

STANDARD ACCESSORIES

• Doppler transducer

• Toco transducer

• Event marker

• Printer paper

• Gel

• Belts

• Manual

Dispositivo Medico
Dispositivo medico
unità
1 pz.
NSIS
213420
CND
Z12080103
UMDNS
12610
Parafarm
903141430
Classe Medicale
II B
New
No reviews

16 other products in the same category: