PC-900B CAPNOGRAPH AND OXIMETER
PC-900B CAPNOGRAPH AND OXIMETER
PC-900B CAPNOGRAPH AND OXIMETER
PC-900B CAPNOGRAPH AND OXIMETER
PC-900B CAPNOGRAPH AND OXIMETER
PC-900B CAPNOGRAPH AND OXIMETER
PC-900B CAPNOGRAPH AND OXIMETER
PC-900B CAPNOGRAPH AND OXIMETER
PC-900B CAPNOGRAPH AND OXIMETER
PC-900B CAPNOGRAPH AND OXIMETER

PC-900B CAPNOGRAPH AND OXIMETER

33698
€2,000.00
VAT excluded
€2,100.00 tax 5% incl.
EtCO2

• EtCO2/CO2 range: 0-150 mmHg (0-20 kPa, or 0-20% (V/V))

• Accuracy:

• ±2 mmHg when 0-40 mmHg

• ±5% (reading) when > 41-70 mmHg

• ±8% (reading) when > 71-100 mmHg

• ±10% (reading) when > 101-150 mmHg

• Update: Every breath, 10, 20 or 30 sec selectable

• Trend length: 24 hours Respiration rate

• Range: 3-150 breaths/min

• Accuracy: ±1% (reading) or ±1 times/min whichever is greater

• Trend length: 24 hours

• Flux: 50-250 cc/min selectable SpO2

• Oximetry saturation range: 0-100%

• Accuracy: ±2% when 70-100%, ±3% when 50-69%

• Trend length: 24 hours

• Pulse rate

• Range: 30-250 bpm

• Accuracy: ±2 bpm or ±2% (reading) when 30-250 bpm

• Trend length: 24 hours Power supply

• AC input consumption: 100-250 V, 50-60 Hz, 5 W

• Battery: Built-in rechargeable lithium battery - 3.6 V, 3000 mAh

• Working time: 10 hours

• Dimension: 70x160xh 40 mm

• Weight: 600 g

 
Capnograph and oximeter PC-900B This innovative and handheld capnograph and oximeter is ideal for monitoring the most severe conditions of patients. It provides reliable SpO2 and pulse rate measurements thanks to its unique MoveOxy™ technology specially conceived for SpO2. It offers an accurate monitoring even in weak pulse signals condition and reliable monitoring in movement. Display of graphical trends and plethysmographic waveform. - 3.5" TFT display showing EtCO2, RR and SpO2, PR - lung pressure and temperature compensation (BTPS compensation) - for intubated or non-intubated patients - graphic trend storage up to 24 hours - USB cable to transfer data on PC Dimension: 70 x 160 x h 40 mm. Weight: 600 g. Internal languages: GB, IT, ES, NL, DE.

TECNICAL SPECIFICATIONS

EtCO2

• EtCO2/CO2 range: 0-150 mmHg (0-20 kPa, or 0-20% (V/V))

• Accuracy:

• ±2 mmHg when 0-40 mmHg

• ±5% (reading) when > 41-70 mmHg

• ±8% (reading) when > 71-100 mmHg

• ±10% (reading) when > 101-150 mmHg

• Update: Every breath, 10, 20 or 30 sec selectable

• Trend length: 24 hours Respiration rate

• Range: 3-150 breaths/min

• Accuracy: ±1% (reading) or ±1 times/min whichever is greater

• Trend length: 24 hours

• Flux: 50-250 cc/min selectable SpO2

• Oximetry saturation range: 0-100%

• Accuracy: ±2% when 70-100%, ±3% when 50-69%

• Trend length: 24 hours

• Pulse rate

• Range: 30-250 bpm

• Accuracy: ±2 bpm or ±2% (reading) when 30-250 bpm

• Trend length: 24 hours Power supply

• AC input consumption: 100-250 V, 50-60 Hz, 5 W

• Battery: Built-in rechargeable lithium battery - 3.6 V, 3000 mAh

• Working time: 10 hours

• Dimension: 70x160xh 40 mm

• Weight: 600 g

STANDARD ACCESSORIES

• 2 water filters

• USB data cable

• Support base

• 2 sampling lines

• Nasal CO2 sampling cannula

• Manual GB, IT

• 2 airway adaptors

• Silicone protective case

• SpO2 probe

• Carrying bag

CND
Z1203019003
GMDN
36872
Classe Medicale
II B
Dispositivo Medico
Dispositivo medico
unità
1 pz.
NSIS
1519884
45 Items
New
No reviews

16 other products in the same category:

Product added to compare.