DefiMonitor XD100 DEFIBRILLATOR manual + AED
DefiMonitor XD100 DEFIBRILLATOR manual + AED

DefiMonitor XD100 DEFIBRILLATOR manual + AED

35374
€6,620.00
VAT excluded
€8,076.40 tax 22% incl.
Defibrillation

• Wave: biphasic, current controlled impulse

• Energy (automatic mode): 140-360 J

• Manual energy stages: 5J, 10J, 20J, 30J, 50J, 100J, 200J, 300J, 360J

• Charging time: < 6 sec for 200 J

• Cardio version: manual activation, QRS marker ECG

• Derivation: - Eindhoven I, II, III - Goldberger, aVR, aVF, aVL

• Patient's resistance: 23-200 Ohm

• Heart rate: 30-300 per min VF: recogniton

• VF recogniton

• Analysis time 7-12 sec

• VF threshold 200 µV

• Asystole threshold < 200 µV

• Artefact, Pacemaker detection Thermal printer

• Resolution: 200 dpi

• Advance: 25 mm/s, 50 mm/s TFT LCD blue-mode monitor

• 115 x 86 mm (diagonal 4.7"/120 mm)

• 320 x 240 pixels Electrodes

• Adhesive electrodes, 3 years shelf life

• Cable length 3.5 m Save pads connect Data backup

• Removable memory 512 MB

• Data/Voice recording > 90 h

• Data/Voice recording > 75 h Power supply

• Voltage 90-264 V, 50/60 Hz Rechargeable Lithium-ion battery (LiFePO4)

• Capacity 2.5 Ah Voltage: 14.4 V

• Discharges 150-200 J

• Monitoring 5 h Charging time: 2.5 h Resuscitation guidelines

• Selectable AHA/ERC Standards

• IEC60601-1:1988+A1:1991+A2:1995 (Electrical Safety of Med. Electrical Devices)

• IEC60601-1-2:2001 (Electromagnetic compatibility)

• IEC60601-1-4:1996+A1:1999 (Programmable electrical medical systems)

• IEC60601-2-4:2002 (Defibrillators)

• EN1789:2003 (Ambulance standard)

• Protection class IP33

 
The sophisticated high performance instrument with multifunctional features. It combines a compact product design, proved and tested in practice with the highest possible degree of safety and user friendly handling. Range of 8 manual (XD1, XD3, XD10, XD30) or manual + AED (XD100, XD300, XD110, XD330) defibrillators with or without SpO2 and external pacer. Supplied with adult/pediatric paddles, disposable adult Save Pads, connect cable, ECG cable, power cable, 1 tube gel, 1 paper roll. Standard software: GB, FR, DE, IT, ES, KT, PT, RO, TR, CN. Manual: GB, IT (on request DE, ES, PT, RU, UA). Other softwares available on request: CZ, FI, HU, NL, NO, PL, RU, SE, DK, GR, LT, JU, AE, BR, CN, IR, JP, TH, US. Size: 33 x 29 x 16 cm

TECNICAL SPECIFICATIONS

Defibrillation

• Wave: biphasic, current controlled impulse

• Energy (automatic mode): 140-360 J

• Manual energy stages: 5J, 10J, 20J, 30J, 50J, 100J, 200J, 300J, 360J

• Charging time: < 6 sec for 200 J

• Cardio version: manual activation, QRS marker ECG

• Derivation: - Eindhoven I, II, III - Goldberger, aVR, aVF, aVL

• Patient's resistance: 23-200 Ohm

• Heart rate: 30-300 per min VF: recogniton

• VF recogniton

• Analysis time 7-12 sec

• VF threshold 200 µV

• Asystole threshold < 200 µV

• Artefact, Pacemaker detection Thermal printer

• Resolution: 200 dpi

• Advance: 25 mm/s, 50 mm/s TFT LCD blue-mode monitor

• 115 x 86 mm (diagonal 4.7"/120 mm)

• 320 x 240 pixels Electrodes

• Adhesive electrodes, 3 years shelf life

• Cable length 3.5 m Save pads connect Data backup

• Removable memory 512 MB

• Data/Voice recording > 90 h

• Data/Voice recording > 75 h Power supply

• Voltage 90-264 V, 50/60 Hz Rechargeable Lithium-ion battery (LiFePO4)

• Capacity 2.5 Ah Voltage: 14.4 V

• Discharges 150-200 J

• Monitoring 5 h Charging time: 2.5 h Resuscitation guidelines

• Selectable AHA/ERC Standards

• IEC60601-1:1988+A1:1991+A2:1995 (Electrical Safety of Med. Electrical Devices)

• IEC60601-1-2:2001 (Electromagnetic compatibility)

• IEC60601-1-4:1996+A1:1999 (Programmable electrical medical systems)

• IEC60601-2-4:2002 (Defibrillators)

• EN1789:2003 (Ambulance standard)

• Protection class IP33

Classe Medicale
II B
Dispositivo Medico
Dispositivo medico
unità
1 pz.
NSIS
208581
CND
Z12030501
GMDN
11-129
4 Items