DIATERMO MB 200 - mono-bipolar 200 Watt
DIATERMO MB 200 - mono-bipolar 200 Watt

DIATERMO MB 200 - mono-bipolar 200 Watt

30542
€1,441.00
VAT excluded
€1,758.02 tax 22% incl.
Maximum output power CUT (W): 200 250Ohm (Crest factor 1,5) Maximum output power CUT 90% (W): 200 250Ohm (Crest factor 1,6) Maximum output power CUT 80% (W): 200 250Ohm (Crest factor 1,7) Maximum output power CUT 70% (W): 200 250Ohm (Crest factor 1,8) Maximum output power BLEND (W): 120 200Ohm (Crest factor 2,1) Maximum output power COAG FORCED (W): 150 150Ohm (Crest factor 2,0) Maximum output power COAG SOFT (W): 90 100Ohm (Crest factor 1,7) Maximum output power BIPOLAR COAG (W): 100 100Ohm (Crest factor 1,5) Maximum output power BIPOLAR CUT (W): 120 250Ohm (Crest factor 1,5) Working frequency: 600 kHz Weight kg: 8 Size LxHxD mm: 360x150x265 Selectable mains power(Vac): 115 - 230 Mains frequency (Hz): 50-60 Fuses 115Vac - 230Vac (5x20) TIMED: 2x6,3A - 2x3,15A Power accuracy output warning system

• Split or not split patient plate allowed

• Electrical Class (EN60601 - 1) I CF MDD 93/42/EEC Class II b Patient circuit F Duty cycle (action/pause) in seconds 10/30

 
DIATERMO MB 200 - 200 W DIATERMO MB200 is a HF electrosurgical unit suitable to perform middle monopolar or bipolar electrosurgery. The available waveforms and peak voltage value, as well as the accurate HF leakage current operation for polypectomy, TURP, intrauterine resections, endometriosis excision, etc. The units allow the accurate preset of the output power with as low as 1 Watt resolution and to perform coagulation by high crest factor current, to get an elevated thermal effect, as well as with low voltage low crest factor current, to get coagulation in absence of carbonization. Ten different programs related to ten different operative conditions could be stored and easily recalled by the surgeon. The use of either split or normal neutral plates are allowed. A special electronic circuit (Skin Plate Electronic Control) continuously checks if the plate is safely connected to the patient and detects unwanted short circuit in the connecting cable. An over time warning (OVT) is provided to prevent excessive heating of the tissue around the surgical target due to too long current delivery time.

TECNICAL SPECIFICATIONS

Maximum output power CUT (W): 200 250Ohm (Crest factor 1,5) Maximum output power CUT 90% (W): 200 250Ohm (Crest factor 1,6) Maximum output power CUT 80% (W): 200 250Ohm (Crest factor 1,7) Maximum output power CUT 70% (W): 200 250Ohm (Crest factor 1,8) Maximum output power BLEND (W): 120 200Ohm (Crest factor 2,1) Maximum output power COAG FORCED (W): 150 150Ohm (Crest factor 2,0) Maximum output power COAG SOFT (W): 90 100Ohm (Crest factor 1,7) Maximum output power BIPOLAR COAG (W): 100 100Ohm (Crest factor 1,5) Maximum output power BIPOLAR CUT (W): 120 250Ohm (Crest factor 1,5) Working frequency: 600 kHz Weight kg: 8 Size LxHxD mm: 360x150x265 Selectable mains power(Vac): 115 - 230 Mains frequency (Hz): 50-60 Fuses 115Vac - 230Vac (5x20) TIMED: 2x6,3A - 2x3,15A Power accuracy output warning system

• Split or not split patient plate allowed

• Electrical Class (EN60601 - 1) I CF MDD 93/42/EEC Class II b Patient circuit F Duty cycle (action/pause) in seconds 10/30

STANDARD ACCESSORIES

• MB two-button autoclavable handle (30536)

• MB waterproof foot-switch 30577 (usable in alternative to handle)

• MB flat neutral metal plate with cable (30564)

• Kit 10 short standard electrodes, diam. 2.4 mm

• Power cable 2 m

• Manual: available in GB, IT

Parafarm
903152078
Classe Medicale
II B
Dispositivo Medico
Dispositivo medico
unità
1 pz.
NSIS
100211
CND
Z12010902
GMDN
44776
83 Items
New
No reviews

6 other products in the same category:

Product added to compare.