General

• Dimensions/Weight: 238x163xh 250 mm/4 kg

• Trace: 6 waveform (ECGx2, SpO2, RR or EtCO2 IBPx2)

• Indicators: categorized alarms (3 priority levels), visual alarm lamp handle, QRS beep, SpO2 pulse beep, heart rate, SpO2 pulse pitch tone battery status, external power LED

• Thermal printer: 25, 50 mm/sec (paper width 58 mm)

• Battery: Rechargeable Li-ion (3 hours operating time)

• Interfaces: LAN digital output for transferring data Nurse call system connection defibrillator sync. output

• DC input connector:18 VDC, 2.8A max

• Operating voltage: 100-240 V, 50-60 Hz SpO2

• % Saturation Range: 0% to 100% ±2 digits (70 to 100%)

• Pulse Rate Range: 30 to 254 bpm ±2 bpm ECG

• Lead type: 3-lead, 5-lead

• Lead selection: 3-lead: I, II, III

• ECG Waveforms: 3-lead 1 channel 5-lead: 1/2/7 channels

• Heart rate range: Adult: 30-300 bpm Neonate/pediatric: 30-350 bpm

• Heart rate accuracy: ± 1 bpm or ± 1%, wichever is greater

• Sweep speed: 6.25, 12.5, 25, 50 mm/sec.

• Filter: Diagnoses: 0.05 to 150 Hz Monitoring 0.5 to 40 Hz Moderate: 0.5 to 25 Hz Maximum: 5 to 25 Hz

• S-T Segment detection range: - 2.0 to 2.0 mV

• Arrhythmia analysis: Asystole, Vtach, Vfib, Bigeminy, Accvent Couplet, Irregular, Pause, Pvc, Ront, Trigeminy, Vbrady, Shortrun

• Pacemaker detection mode: Indicator on waveform display (user selectable)

• Protecion: against electrosurgical interference and defibrillation NIBP

• Technique: Oscillometric with linear deflation

• Pressure range: 0 to 300 mmHg ± 3 mmHg

• Measurement Modes: Manual-Automatic-Continuous

• Safety pressure: Adult: 300 mmHg Neonate: 150 mmHg

• Measurement range: Adult pressure: 20 to 260 mmHg Pediatric pressure: 20 to 160 mmHg Neonate pressure: 20 to 130 mmHg Pulse rate: 30-220 bpm

• Accuracy: meets accuracy requirements of ANSI/AAMI ISO 81060-2-2013 Respirations

• Range: 5 to 120 breaths/min ±1 b/min

• Apnea alarm: yes Temperature Unit

• Range: 0° to 50°C (32°F to 122°F)

• Accuracy: ± 0.1°C (25 to 50°C), ± 0.2°C (0 to 24°C)

• Compatible with: YSI Series 400 Temperature Probes IBP - option

• Channels: 2

• Measuring range: -50 to 300 mmHg

• Measuring accuracy: ± 1 mmHg (<100 mmHg) ± 1 % of reading(>100 mmHg)

• Pulse rate counting range: 0 to 300 beats/min

• Zero balancing: range ± 200 mmHg accuracy ± 1 mmHg drift ± 1 mmHg over 24 hours

• Transducer sensitivity: 5µV/V mmHg EtCO2 - Respironics option

• Measurement mode: Sidestream or Mainstream

• Measurement range: 0~150 mmHg, 0 to 19%

• Respiration range: 2~150 bpm

• Accuracy: ± 2 mmHg, 0~40 mmHg ± 5%, 41~70 mmHg ± 8%, 71~100 mmHg ± 10%, 101~150 mmHg

• Respiration accuracy: ± 1 breath per minute

 
GIMA BM5 pro MONITOR - 10.4” Touch screen colour TFT LCD - 7 ch ECG Enhanced & expandable multi-parameter patient monitor - 10.4" touch screen colour TFT LCD with 6 waveforms - individual sweep speed setting for each parameter - 168 full hours trend data are stored - SpO2 measurement with every low perfusion detection - screen freeze on/off - oxyCRG, drug calculation - external HDMI output for large screens - connection to central station using LAN or W-LAN - optional - Li-ion battery with longer time life (3 hours of continuous operation) - real time bed to bed connectivity, max 8 monitors without server or central station - EMR direct HL7 with editable menu - enhanced & expandable multi-parameters:

• Mainstream/Sidestream EtCO2 optional

• high-performance suntech NIBP (BM5ICU) - high-performance ECG detection and analysis:

• enhanced input impedance for dry skin or electrode patch

• ST level, PVC count, real-time display

• 13 kinds of arrhythmia analysis

• pacemaker detection function - enhanced data management:

• graphical and tabular trends

• USB memory storage

• 20 cases - 1 sec. alarm waveform are stored, reviewed and printed Arrhythmia analysis: VTAG, VFIB, ASYSTOLIC Pacemaker detection indicated on the ECG waveform display. Selectable software language (GB, DE, FR, IT, PT, PL, RO, HU, ES, CZ, BG, RU, TR, CN).

TECNICAL SPECIFICATIONS

General

• Dimensions/Weight: 238x163xh 250 mm/4 kg

• Trace: 6 waveform (ECGx2, SpO2, RR or EtCO2 IBPx2)

• Indicators: categorized alarms (3 priority levels), visual alarm lamp handle, QRS beep, SpO2 pulse beep, heart rate, SpO2 pulse pitch tone battery status, external power LED

• Thermal printer: 25, 50 mm/sec (paper width 58 mm)

• Battery: Rechargeable Li-ion (3 hours operating time)

• Interfaces: LAN digital output for transferring data Nurse call system connection defibrillator sync. output

• DC input connector:18 VDC, 2.8A max

• Operating voltage: 100-240 V, 50-60 Hz SpO2

• % Saturation Range: 0% to 100% ±2 digits (70 to 100%)

• Pulse Rate Range: 30 to 254 bpm ±2 bpm ECG

• Lead type: 3-lead, 5-lead

• Lead selection: 3-lead: I, II, III

• ECG Waveforms: 3-lead 1 channel 5-lead: 1/2/7 channels

• Heart rate range: Adult: 30-300 bpm Neonate/pediatric: 30-350 bpm

• Heart rate accuracy: ± 1 bpm or ± 1%, wichever is greater

• Sweep speed: 6.25, 12.5, 25, 50 mm/sec.

• Filter: Diagnoses: 0.05 to 150 Hz Monitoring 0.5 to 40 Hz Moderate: 0.5 to 25 Hz Maximum: 5 to 25 Hz

• S-T Segment detection range: - 2.0 to 2.0 mV

• Arrhythmia analysis: Asystole, Vtach, Vfib, Bigeminy, Accvent Couplet, Irregular, Pause, Pvc, Ront, Trigeminy, Vbrady, Shortrun

• Pacemaker detection mode: Indicator on waveform display (user selectable)

• Protecion: against electrosurgical interference and defibrillation NIBP

• Technique: Oscillometric with linear deflation

• Pressure range: 0 to 300 mmHg ± 3 mmHg

• Measurement Modes: Manual-Automatic-Continuous

• Safety pressure: Adult: 300 mmHg Neonate: 150 mmHg

• Measurement range: Adult pressure: 20 to 260 mmHg Pediatric pressure: 20 to 160 mmHg Neonate pressure: 20 to 130 mmHg Pulse rate: 30-220 bpm

• Accuracy: meets accuracy requirements of ANSI/AAMI ISO 81060-2-2013 Respirations

• Range: 5 to 120 breaths/min ±1 b/min

• Apnea alarm: yes Temperature Unit

• Range: 0° to 50°C (32°F to 122°F)

• Accuracy: ± 0.1°C (25 to 50°C), ± 0.2°C (0 to 24°C)

• Compatible with: YSI Series 400 Temperature Probes IBP - option

• Channels: 2

• Measuring range: -50 to 300 mmHg

• Measuring accuracy: ± 1 mmHg (<100 mmHg) ± 1 % of reading(>100 mmHg)

• Pulse rate counting range: 0 to 300 beats/min

• Zero balancing: range ± 200 mmHg accuracy ± 1 mmHg drift ± 1 mmHg over 24 hours

• Transducer sensitivity: 5µV/V mmHg EtCO2 - Respironics option

• Measurement mode: Sidestream or Mainstream

• Measurement range: 0~150 mmHg, 0 to 19%

• Respiration range: 2~150 bpm

• Accuracy: ± 2 mmHg, 0~40 mmHg ± 5%, 41~70 mmHg ± 8%, 71~100 mmHg ± 10%, 101~150 mmHg

• Respiration accuracy: ± 1 breath per minute

STANDARD ACCESSORIES

3 lead patient cable (ECG) SpO2 sensor - reusable Disposable electrodes: 10 pcs SpO2 sensor extension cable 2 m NIBP tubing - 3m Thermal printer 58 mm Reusable child and adult cuff DC adaptor (18 VDC, 2.5A) Battery User manual: GB, IT

Classe Medicale
II B
Dispositivo Medico
Dispositivo medico
unità
1 pz.