GIMA BM5 PRO MULTIPARAMETER MONITOR with Touch Screen - 7 ch ECG
• Dimensions/Weight: 238x163xh 250 mm/4 kg
• Trace: 6 waveform (ECGx2, SpO2, RR or EtCO2 IBPx2)
• Indicators: categorized alarms (3 priority levels), visual alarm lamp handle, QRS beep, SpO2 pulse beep, heart rate, SpO2 pulse pitch tone battery status, external power LED
• Thermal printer: 25, 50 mm/sec (paper width 58 mm)
• Battery: Rechargeable Li-ion (3 hours operating time)
• Interfaces: LAN digital output for transferring data Nurse call system connection defibrillator sync. output
• DC input connector:18 VDC, 2.8A max
• Operating voltage: 100-240 V, 50-60 Hz SpO2
• % Saturation Range: 0% to 100% ±2 digits (70 to 100%)
• Pulse Rate Range: 30 to 254 bpm ±2 bpm ECG
• Lead type: 3-lead, 5-lead
• Lead selection: 3-lead: I, II, III
• ECG Waveforms: 3-lead 1 channel 5-lead: 1/2/7 channels
• Heart rate range: Adult: 30-300 bpm Neonate/pediatric: 30-350 bpm
• Heart rate accuracy: ± 1 bpm or ± 1%, wichever is greater
• Sweep speed: 6.25, 12.5, 25, 50 mm/sec.
• Filter: Diagnoses: 0.05 to 150 Hz Monitoring 0.5 to 40 Hz Moderate: 0.5 to 25 Hz Maximum: 5 to 25 Hz
• S-T Segment detection range: - 2.0 to 2.0 mV
• Arrhythmia analysis: Asystole, Vtach, Vfib, Bigeminy, Accvent Couplet, Irregular, Pause, Pvc, Ront, Trigeminy, Vbrady, Shortrun
• Pacemaker detection mode: Indicator on waveform display (user selectable)
• Protecion: against electrosurgical interference and defibrillation NIBP
• Technique: Oscillometric with linear deflation
• Pressure range: 0 to 300 mmHg ± 3 mmHg
• Measurement Modes: Manual-Automatic-Continuous
• Safety pressure: Adult: 300 mmHg Neonate: 150 mmHg
• Measurement range: Adult pressure: 20 to 260 mmHg Pediatric pressure: 20 to 160 mmHg Neonate pressure: 20 to 130 mmHg Pulse rate: 30-220 bpm
• Accuracy: meets accuracy requirements of ANSI/AAMI ISO 81060-2-2013 Respirations
• Range: 5 to 120 breaths/min ±1 b/min
• Apnea alarm: yes Temperature Unit
• Range: 0° to 50°C (32°F to 122°F)
• Accuracy: ± 0.1°C (25 to 50°C), ± 0.2°C (0 to 24°C)
• Compatible with: YSI Series 400 Temperature Probes IBP - option
• Channels: 2
• Measuring range: -50 to 300 mmHg
• Measuring accuracy: ± 1 mmHg (<100 mmHg) ± 1 % of reading(>100 mmHg)
• Pulse rate counting range: 0 to 300 beats/min
• Zero balancing: range ± 200 mmHg accuracy ± 1 mmHg drift ± 1 mmHg over 24 hours
• Transducer sensitivity: 5µV/V mmHg EtCO2 - Respironics option
• Measurement mode: Sidestream or Mainstream
• Measurement range: 0~150 mmHg, 0 to 19%
• Respiration range: 2~150 bpm
• Accuracy: ± 2 mmHg, 0~40 mmHg ± 5%, 41~70 mmHg ± 8%, 71~100 mmHg ± 10%, 101~150 mmHg
• Respiration accuracy: ± 1 breath per minute
• Mainstream/Sidestream EtCO2 optional
• high-performance suntech NIBP (BM5ICU) - high-performance ECG detection and analysis:
• enhanced input impedance for dry skin or electrode patch
• ST level, PVC count, real-time display
• 13 kinds of arrhythmia analysis
• pacemaker detection function - enhanced data management:
• graphical and tabular trends
• USB memory storage
• 20 cases - 1 sec. alarm waveform are stored, reviewed and printed Arrhythmia analysis: VTAG, VFIB, ASYSTOLIC Pacemaker detection indicated on the ECG waveform display. Selectable software language (GB, DE, FR, IT, PT, PL, RO, HU, ES, CZ, BG, RU, TR, CN).
TECNICAL SPECIFICATIONS
General
• Dimensions/Weight: 238x163xh 250 mm/4 kg
• Trace: 6 waveform (ECGx2, SpO2, RR or EtCO2 IBPx2)
• Indicators: categorized alarms (3 priority levels), visual alarm lamp handle, QRS beep, SpO2 pulse beep, heart rate, SpO2 pulse pitch tone battery status, external power LED
• Thermal printer: 25, 50 mm/sec (paper width 58 mm)
• Battery: Rechargeable Li-ion (3 hours operating time)
• Interfaces: LAN digital output for transferring data Nurse call system connection defibrillator sync. output
• DC input connector:18 VDC, 2.8A max
• Operating voltage: 100-240 V, 50-60 Hz SpO2
• % Saturation Range: 0% to 100% ±2 digits (70 to 100%)
• Pulse Rate Range: 30 to 254 bpm ±2 bpm ECG
• Lead type: 3-lead, 5-lead
• Lead selection: 3-lead: I, II, III
• ECG Waveforms: 3-lead 1 channel 5-lead: 1/2/7 channels
• Heart rate range: Adult: 30-300 bpm Neonate/pediatric: 30-350 bpm
• Heart rate accuracy: ± 1 bpm or ± 1%, wichever is greater
• Sweep speed: 6.25, 12.5, 25, 50 mm/sec.
• Filter: Diagnoses: 0.05 to 150 Hz Monitoring 0.5 to 40 Hz Moderate: 0.5 to 25 Hz Maximum: 5 to 25 Hz
• S-T Segment detection range: - 2.0 to 2.0 mV
• Arrhythmia analysis: Asystole, Vtach, Vfib, Bigeminy, Accvent Couplet, Irregular, Pause, Pvc, Ront, Trigeminy, Vbrady, Shortrun
• Pacemaker detection mode: Indicator on waveform display (user selectable)
• Protecion: against electrosurgical interference and defibrillation NIBP
• Technique: Oscillometric with linear deflation
• Pressure range: 0 to 300 mmHg ± 3 mmHg
• Measurement Modes: Manual-Automatic-Continuous
• Safety pressure: Adult: 300 mmHg Neonate: 150 mmHg
• Measurement range: Adult pressure: 20 to 260 mmHg Pediatric pressure: 20 to 160 mmHg Neonate pressure: 20 to 130 mmHg Pulse rate: 30-220 bpm
• Accuracy: meets accuracy requirements of ANSI/AAMI ISO 81060-2-2013 Respirations
• Range: 5 to 120 breaths/min ±1 b/min
• Apnea alarm: yes Temperature Unit
• Range: 0° to 50°C (32°F to 122°F)
• Accuracy: ± 0.1°C (25 to 50°C), ± 0.2°C (0 to 24°C)
• Compatible with: YSI Series 400 Temperature Probes IBP - option
• Channels: 2
• Measuring range: -50 to 300 mmHg
• Measuring accuracy: ± 1 mmHg (<100 mmHg) ± 1 % of reading(>100 mmHg)
• Pulse rate counting range: 0 to 300 beats/min
• Zero balancing: range ± 200 mmHg accuracy ± 1 mmHg drift ± 1 mmHg over 24 hours
• Transducer sensitivity: 5µV/V mmHg EtCO2 - Respironics option
• Measurement mode: Sidestream or Mainstream
• Measurement range: 0~150 mmHg, 0 to 19%
• Respiration range: 2~150 bpm
• Accuracy: ± 2 mmHg, 0~40 mmHg ± 5%, 41~70 mmHg ± 8%, 71~100 mmHg ± 10%, 101~150 mmHg
• Respiration accuracy: ± 1 breath per minute
STANDARD ACCESSORIES
3 lead patient cable (ECG) SpO2 sensor - reusable Disposable electrodes: 10 pcs SpO2 sensor extension cable 2 m NIBP tubing - 3m Thermal printer 58 mm Reusable child and adult cuff DC adaptor (18 VDC, 2.5A) Battery User manual: GB, IT
- Dispositivo Medico
- Dispositivo medico
- unità
- 1 pz.
- Classe Medicale
- II B