Input way: Floating and defibrillation protection Lead: Standard 12 leads Patient leak current: < 10 µA Input impedance: = 50 Megaohm Frequency response: 0.05 - 150 Hz (-3 - + 0,4 dB) Time constant: = 3.2 s CMRR: >60 dB, > 100 dB (adding filter) EMG interference filter: 25/35 Hz (-3 dB) Thermal paper: 210 mm x 20 m high-speed Paper speed: - Auto and rhythm record: 25, 50 mm/s, ±5% - Manual record: 5, 6.25, 10, 12.5, 25, 50 mm/s, ±5% Sensitivity selections: 2.5, 5, 10, 20, 40 mm/mV, ±5%. (Standard sensitivity is 10 mm/mV ±0.2 mm/mV.) Auto record: Record setup according to auto record format and mode, automatically changing leads, measuring and analyzing. Rhythm record: Record setup according to rhythm record format and mode, automatically measuring and analyzing. Manual record: Record setup according to manual record format, manually changing leads. Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1) Product safety type: Class I CF defibrillation and pacing protection Size: 334 x 320 x 85 mm Power: AC: 100-240 V, 50/60 Hz DC: 14.8 V, 3700mAh rechargeable lithium battery

 
- 8” TFT display, 800x600 dots high resolution colour LED backlight - simultaneous 12 leads acquisition and display - digital signal technique, AC filter, baseline filter, EMG filter - auto-analysis and auto-interpretation - Multi-mode display and printing, such as 12, 6+1 (rhythm), 6, rhythm 12, rhythm 10, rhythm 8, rhythm 6. Manual, Freeze etc - 0.5 built-in lithium rechargeable battery - 2 USB and LAN Socket for uploading data to PC - built-in flash memory. Stores more than 1,000 files Multi-language internal software: GB, FR, IT, ES, PT, PL, SI, TR, RU, KZ, CN.

TECNICAL SPECIFICATIONS

Input way: Floating and defibrillation protection Lead: Standard 12 leads Patient leak current: < 10 µA Input impedance: = 50 Megaohm Frequency response: 0.05 - 150 Hz (-3 - + 0,4 dB) Time constant: = 3.2 s CMRR: >60 dB, > 100 dB (adding filter) EMG interference filter: 25/35 Hz (-3 dB) Thermal paper: 210 mm x 20 m high-speed Paper speed: - Auto and rhythm record: 25, 50 mm/s, ±5% - Manual record: 5, 6.25, 10, 12.5, 25, 50 mm/s, ±5% Sensitivity selections: 2.5, 5, 10, 20, 40 mm/mV, ±5%. (Standard sensitivity is 10 mm/mV ±0.2 mm/mV.) Auto record: Record setup according to auto record format and mode, automatically changing leads, measuring and analyzing. Rhythm record: Record setup according to rhythm record format and mode, automatically measuring and analyzing. Manual record: Record setup according to manual record format, manually changing leads. Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1) Product safety type: Class I CF defibrillation and pacing protection Size: 334 x 320 x 85 mm Power: AC: 100-240 V, 50/60 Hz DC: 14.8 V, 3700mAh rechargeable lithium battery

STANDARD ACCESSORIES

1 ECG cable 1 ground wire 1 set limb electrode clamp 1 paper roll 1 set chest electrodes Power connection USB connection Rechargeable battery Software (same languages as internal software) Manual: GB, IT