100G ECG - 1 channel with monitor
100G ECG - 1 channel with monitor
100G ECG - 1 channel with monitor
100G ECG - 1 channel with monitor
100G ECG - 1 channel with monitor
100G ECG - 1 channel with monitor
100G ECG - 1 channel with monitor
100G ECG - 1 channel with monitor

100G ECG - 1 channel with monitor

33220
€425.00
VAT excluded
€446.25 tax 5% incl.
ECG instrument Input

• Safety Type: Class I, type CF applied part, which has defibrillation-proof applied part

• Lead Standard 12 leads

• Input way: Floating and defibrillation protection

• Patient leak current: <10µA

• Sampling rate: 800Hz

• A/D conversion: 12bit

• Frequency response 0.05Hz~150Hz (-3dB, + 0.4dB)

• Time constant: >3.2s

• CMRR: >60dB, >100dB(Add filter)

• Enduring polarization voltage: ±500mV

• Noise level: <15µVp-p Dispose Wave Data

• EMG interference filter 35Hz (-3dB)

• AC filter 50Hz/60Hz (=20dB) Waveform output

• Recording way: Thermal printing system

• Recording paper: 50mm(W)×20m(L)

• Sensitivity: 5, 10, 20mm/mV

• Paper speed: - Auto-record: auto leads changing - Rhythm record: 25 mm/s, 50 mm/s - Manual-record: 25 mm/s, 50 mm/s Power supply

• AC: 110-220V, 50/60 Hz

• DC: Lithium battery 7.4V, 2000 mAh Fuse

• 2 pcs Ø5×20mm AC time lag; T250mA/250V(Power Supply:220V) Form

• Size: 315 x 215 x 77 mm

• Net Weight: 1.5 kg

 
- Large LCD display waveform and data - High-resolution thermal printing array system - Frequency response is as high as 150 Hz - Capable of printing continuously on channel trace and annotations including lead mark and parameter such as sensitivity, paper speed and filter operation status - High resolution digital filter inhibits baseline drift without affecting ECG waveform - Floating input circuit meets IEC safety standard - Rechargeable battery supporting more than 50 patient examinations - Internal software: GB, IT, FR, ES, DE, TR. - Manual: GB, IT, ES.

TECNICAL SPECIFICATIONS

ECG instrument Input

• Safety Type: Class I, type CF applied part, which has defibrillation-proof applied part

• Lead Standard 12 leads

• Input way: Floating and defibrillation protection

• Patient leak current: <10µA

• Sampling rate: 800Hz

• A/D conversion: 12bit

• Frequency response 0.05Hz~150Hz (-3dB, + 0.4dB)

• Time constant: >3.2s

• CMRR: >60dB, >100dB(Add filter)

• Enduring polarization voltage: ±500mV

• Noise level: <15µVp-p Dispose Wave Data

• EMG interference filter 35Hz (-3dB)

• AC filter 50Hz/60Hz (=20dB) Waveform output

• Recording way: Thermal printing system

• Recording paper: 50mm(W)×20m(L)

• Sensitivity: 5, 10, 20mm/mV

• Paper speed: - Auto-record: auto leads changing - Rhythm record: 25 mm/s, 50 mm/s - Manual-record: 25 mm/s, 50 mm/s Power supply

• AC: 110-220V, 50/60 Hz

• DC: Lithium battery 7.4V, 2000 mAh Fuse

• 2 pcs Ø5×20mm AC time lag; T250mA/250V(Power Supply:220V) Form

• Size: 315 x 215 x 77 mm

• Net Weight: 1.5 kg

STANDARD ACCESSORIES

• ECG cable - 1 set

• Limb electrode clamp - 1 set

• chest electrodes - 1 set

• Ground wire

• Power connection

• Paper roll

Parafarm
909435442
Classe Medicale
II A
Dispositivo Medico
Dispositivo medico
unità
1 pz.
NSIS
352176
CND
Z12050301
UMDNS
11407
38 Items
New
No reviews

10 other products in the same category:

Product added to compare.